INFLUENCE OF THE DATE OF CALCULATION OF THE INSOLATION DURATION ON THE PARAMETERS OF A COMPACTED BUILDING
Abstract
The influence of the date of computation of insolation duration on the acceptable mutual position
of buildings and their height has been studied. The relevance of the research is explained by
changing of the date of normative insolation computation from March 22 to April 22, which had
been adopted in Russia. The study has been performed using 3D computer modeling of buildings
and building of the fields displaying the duration of insolation on the building walls and surrounding
territories. An algorithm of computing the insolation duration and of building the fields is given.
It is demonstrated that when calculating the insolation with the new date of April 22, it is acceptable
to increase the height of buildings and reduce the distance between buildings by 30 %,
as well as to reduce the angle between a northern building wall and the parallel from 48° to 24°.
The specifics of insolation for L-shape buildings has been revealed. It is shown that with shifting
the calculation date from March to April, the insolation on inner walls decreases. The study of
this special case has been performed. Dependencies have been built for duration of insolation on the
inner walls of L-shape buildings depending on the computation date throughout the year, and on the
increasing of the distance between the calculation point and the angle edge. The geometrical model
explaining the revealed effect is provided.
The examples are given, which show negative manifestations of the revealed effect. Here, new
buildings, calculated for the insolation as of March 22, have been brought to unacceptable insulation
as per April 22 norms.
The studies have been performed in AutoCAD package using the system of automatic computing
and building of insolation fields.
Keywords
Full Text:
PDF (Русский)References
СанПиН 2.2.1/2.1.1.1076-01. Гигиенические требования к инсоляции и солнцезащите помещений жилых и общественных зданий и территорий: утв. Главным государственным санитарным врачом РФ 19 октября 2001 г. – http://best-stroy.ru/
gost/r38/311.
О внесении изменений в санитарные правила и нормы СанПиН 2.2.1/2.1.1.1076-01. – http://docs.cntd.ru/document/420398169
Слукин, В.М. Обеспечение нормированных условий естественного освещения жилых зданий в уплотненной застройке / В.М. Слукин, Л.Н. Смирнов // Академический вестник УралНИИпроект РААСН. – 2011. – № 4. – С. 75–77.
Эксперты: проблема уплотнительной застройки в России нарастает. – https://
urbanlook.ru/eksperty-problema-uplotnitelnojzastrojki-v-rossii-narastaet/
Хейфец, А.Л. Продолжительность инсоляции: автоматизация расчета и учебные аспекты / А.Л. Хейфец // Проблемы координации работы технических вузов в области повышения качества инженерно-графической подготовки студентов: материалы науч.-метод. конф. (с. Дивноморское, 10–16 сентября 2018 г.); Донской гос. техн. ун-т. – Ростов-на-Дону: ДГТУ, 2018. – С. 134–148.
Kheifetc, A.L. Automation of Computation of Insolation Duration in Architectural Design / A.L. Kheifetc // IOP Conference Series: Materials Science and Engineering. – 2018. – Vol. 451. –
P. 012123. – http://iopscience.iop.org/article/10.1088/
-899X/451/1/012123/pdf
Шмаров, И.А. Инсоляция: практика нормирования и расчета / И.А. Шмаров, В.А. Земцов, Е.В. Коркина // Жилищное строительство. – 2016. – № 7. – С. 48–54.
Обновленная методика расчета продолжительности инсоляции помещений и территорий по инсоляционным графикам / И.А. Шмаров, В.А. Земцов, В.В. Земцов, В.А. Козлов // Жилищное строительство. – 2018. – № 6. – С. 24–31.
Росчерком пера нас лишили солнца в квартирах: «Город будет безобразный». – http://
www.mk.ru/social/2018/03/01/roscherkom-pera-naslishili-solnca-v-kvartirakh-gorod-budetbezobraznyy.html
Инженерная 3D-компьютерная графика: учебник и практикум для академического бакалавриата / А.Л. Хейфец, А.Н. Логиновский, И.В. Буторина, В.Н. Васильева; под ред. А.Л. Хейфеца. – 3-е изд., пер. и доп. – М.: Изд-во Юрайт, 2015. – 602 с.
Хейфец, А.Л. Свидетельство о государственной регистрации программы для ЭВМ № 2010613828 Российская Федерация. Программа автоматического расчета инсоляции / А.Л. Хейфец. – Заявка № 2010612286, дата поступления 23.04.2010; зарег. 10.06.2010.
Хейфец, А.Л. Система автоматизированного расчета продолжительности инсоляции / А.Л. Хейфец // Вестник ЮУрГУ. Серия «Строительство и архитектура». – 2007. – Вып. 4,
№ 14(86). – С. 51–54. 13. Хейфец, А.Л. Расчет продолжительности инсоляции в условиях уплотненной застройки / А.Л. Хейфец // Приволжский научный журнал. –
– № 3. – С. 99–105. – http:// www.pnj.nngasu.ru/
word/pnj_3(2012).zip
Архитектурная физика / В.К. Лицкевич, Л.И. Макриенко, И.В. Мигалина и др.; под ред. Н.В. Оболенского. – М.: Архитектура-С, 2007. – 448 с.
Формула Купера. – https://yandex.ru/images/
search?text=формула%20купера%20склонение%20
солнца&stype=image&lr=56&source=wiz
ГОСТ Р 57795-2017. Здания и сооружения. Методы расчета продолжительности инсоляции.
ООО ПКБ «Профиль-Проект». – http:// www.profile-project.ru
Пат. 2505853 Российская Федерация. Способ определения допустимого объема застройки с учетом продолжительности инсоляции при архитектурном проектировании / А.Л. Хейфец,
А.В. Саморуков. – Заявка № 2012128696. Приоритет изобретения 09.07.2012. Срок действия патента до 09.07.2032.
Kheyfets, A.L. Structural Engineering in Terms of Densed Housing System with Allowance for Insolation / A.L. Kheyfets // 21st International Conference in Central Europe on Computer Graphics, Visualization and Computer Vision in cooperation with
EUROGRAPHICS Association. WSCG 2013. Poster
Proceedings. Edited by Vaclav Skala, University of West Bohemia, Czech Republic. S. 25–28. –
http://wscg.zcu.cz/WSCG2013/!_2013-WSCG-PosterProceedings.pdf
Хейфец, А.Л. Инженерная компьютерная графика. AutoCAD. Опыт преподавания и широта взгляда / А.Л. Хейфец. – М.: Диалог МИФИ. – 2002. – 432 с.