ALGORITHMS FOR IN-LINE PRESSURE TRANSMITTERS CONDITION MONITORING

Authors

  • Oleg Yurievich Bushuev South Ural State University, Chelyabinsk
  • Ekaterina Sergeevna Tugova South Ural State University, Chelyabinsk
  • Maria Andreevna Motorina South Ural State University, Chelyabinsk

DOI:

https://doi.org/10.14529/ctcr200306

Keywords:

condition monitoring, pressure transducers, fault detection, noise analysis, standard deviation

Abstract

In the context of the transition of the world industry to new production technologies, the task of monitoring the technical condition of automatic control systems components, including pressure sensors, is urgent. Despite the existence of research and development aimed at creating systems for diagnostics and self-diagnosis of pressure sensors, the degradation mechanisms of mechanical parts of sensors and diagnostics algorithms during operation remain insufficiently studied.

Aim. Propose algorithms for condition monitoring of the mechanical and hydraulic system of in-line pressure transducers.

Materials and methods. This study is based on tests conducted on pressure modules with defects that simulate the lack of liquid in the separation cavity of the mechanical and hydraulic system of the transducer, manufactured by the industrial partner. The method of fault diagnosis is based on the analysis of statistical characteristics of the ADC signal of the pressure modules.

Results. During the tests, hypotheses were confirmed about the dependence of the standard deviation of the output signal of the pressure module on the volume of liquid-oil in the channel. Based on the obtained data, algorithms for diagnosing the technical condition of the pressure sensor were proposed, which use the values of the sensor signal STD as a diagnostic parameter. The algorithms provide verification of the applicability conditions of the considered method and use additional information about the technological process. The problems that need to be solved for the practical implementation of algorithms in real production are formulated.

Conclusion. The proposed algorithms for condition monitoring of the pressure sensor differ from the known diagnostic algorithms in that they use the results of experimental studies and are aimed at detecting a malfunction of the mechanical part of the sensors. Algorithms can be used to monitor the technical condition of in-line pressure sensors during operation under certain conditions that need to be clarified in the course of further research and field tests.

Author Biographies

Oleg Yurievich Bushuev, South Ural State University, Chelyabinsk

доцент кафедры информационно-измерительной техники, старший научный сотрудник научно-исследовательской лаборатории технической самодиагностики и самоконтроля приборов и систем

Ekaterina Sergeevna Tugova, South Ural State University, Chelyabinsk

инженер-исследователь научно-исследовательской лаборатории технической самодиагностики и самоконтроля приборов и систем

Maria Andreevna Motorina, South Ural State University, Chelyabinsk

студент кафедры информационно-измерительной техники

References

Княгинин, В.Н. Новая технологическая революция: вызовы и возможности для России: экспертно-аналитический доклад / В.Н. Княгинин. – М.: Центр стратегических разработок, 2017. – 136 с.

Feng, Z. Design and implementation of a self-validating pressure sensor / Z. Feng, Q. Wang, K. Shida // IEEE SENSORS JOURNAL. – 2009. – V. 9, no. 3. – P. 207–218.

Taymanov, R. SENSOR DEVICES WITH METROLOGICAL SELF-CHECK / R. Taymanov, K. Sapozhnikova, I. Druzhinin // Sensors and Transducers. – 2011. – V. 133, № 10. – P. 30–45.

Belozubov, E.M. Metrological Self-Checking of Smart Sensors of Measurement and Control Systems/ E.M. Belozubov, V.A. Vasil’ev, P.S. Chernov // Meas Tech. – 2018. – V.61. – P. 660–669.

Ларионов, В.А. Способ метрологического самоконтроля тензорезистивного датчика давления / В.А. Ларионов // Метрология. – 2020. – No. 1. – С. 48–68.

Detecting changes in the condition of a pressure transducer by analyzing its output signal / O.Yu. Bushuev, A.S. Semenov, A.O. Chernavskiy, A.L. Shestakov // Proceedings of XX IMEKO World Congress “Metrology for Green Growth”, Busan, Republic of Korea. – September 9–14, 2012.

Бушуев, О.Ю. Экспериментальное исследование возможности диагностики состояния тензометрического преобразователя давления на основе анализа его выходного сигнала / О.Ю. Бушуев, А.С. Семенов // Вестник ЮУрГУ. Серия «Компьютерные технологии, управление, радиоэлектроника». – 2012. – Т. 17, № 35(294). – С. 65–68.

Семенов, А.С. Модель самодиагностирующегося датчика с нелинейной функцией преобразования / А.С. Семенов, А.Л. Шестаков // «Средства и технологии получения и обработки измерительной информации»: сборник трудов международной научно-технической конференции «Шляндинские чтения» (10–12 нояб. 2014 г.). – Пенза, 2014. – С. 142–147.

Patent No. 7254518 U.S. Pressure Transmitter with Diagnostics / E. Eryurek, K. Kavaklioglu. – Appl. 15.03.2004; publ. 07.08.2007; filed by Rosemount Inc.

Patent No. 7680549 U.S. Diagnostics in Industrial Process Control System, appl. 04.04.2006, publ. 16.03.2010 / Kavaklioglu, K., Wehrs, D.L., Lattimer, D.R., Eryurek, E..; filed by Fisher Rosemount Systems Inc.

Wehrs, D. Detection of Plugged Impulse Lines Using Statistical Process Monitoring Technology / D. Wehrs. – Emerson Process Management, 2006. – 7 p.

Hashemian, H. Sensor performance and reliability / H. Hashemian. – ISA: The Instrumentation, Systems, and Automation Society, 2005. – 306 p.

Online Sensor Calibration Assessment in Nuclear Power Systems / J. Coble, P. Ramuhalli, R. Meyer, H. Hashemian // IEEE: Instrumentation & Measurement Magazine. – 2013. – V. 16. – No. 3. – P. 32–37.

Calibration monitoring for sensor calibration interval extension: Identifying technical gaps / J. Coble, P. Ramuhalli, R. Meyer et al. // Future of Instrumentation International Workshop (FIIW) Proceedings. – 2012. – P. 1–4.

Hashemian, H. Measurement of Dynamic Temperatures and Pressures in Nuclear Power Plants / H. Hashemian. – Electronic Thesis and Dissertation Repository. – 2011. – No. 189.

Blázquez, J. When a pressure transmitter leaves the linearity: the Rosemount Case / J. Bláz-quez // Int. J. Nuclear Energy Science and Technology. – 2006. – V. 2, No. 3. – P. 299–307.

Published

2020-08-04

Issue

Section

Instrument Engineering, Metrology and Information and Measuring Devices and Systems