Estimated Duration of Effective Operation of Autonomous Passive Residual Heat Removal System (PRHRS) at Comparing Heat Removal to Cooling Water vs Ambient Air

Authors

  • I. I. Sviridenko Sevastopol State University, Sevastopol

DOI:

https://doi.org/10.14529/power160301

Keywords:

nuclear power plants with VVER, safety, passive heatsink, final heat absorber, PRHRS, thermosiphon heat transfer equipment

Abstract

The article presents the layout and operation principles of an autonomous thermosiphon-based passive residual heat removal system (PRHRS) from the primary circuit of the nuclear power plant with VVER reactor
under beyond-design accident conditions with complete long-term blackout, loss of feed water and primary LOCAs. Peculiarities of residual heat removal to water or ambient air by autonomous thermosiphon PRHRS are presented. The results of the analytical evaluation and estimated duration of effective operation of the autonomous PRHRS removing residual heat to water and air and providing a safe stable reactor condition are shown. The results were received based on numerical simulation using RELAP5 / MOD3.4 thermal-hydraulic code. The comparative evaluation of the results is made. The advantages and disadvantages of the use of water vs air as the final heat absorber are analyzed.

Author Biography

I. I. Sviridenko, Sevastopol State University, Sevastopol

-

References

Berkovich V.M., Kopytov I.I., Taranov G.S., and Mal’tsev M.B. Salient Features of Design for New Gene-ration Nuclear Power Station Equipped with Improved Safety VVER-1000 Reactor. Thermal Engineering, 2005, no. 1, pp. 9–16.

Sviridenko I.I. [Use of Ambient Water and Air as Final Heat Repository for PRHRS SG of WWER Power Units]. Jenergeticheskie ustanovki i tehnologii [Power Plants and Technologies], 2016, vol. 2, no. 2, pp. 32–40.

(in Russ.)

Afrov A.M., et al. Metodicheskie osobennosti obosnovanija passivnyh sistem bezopasnosti AJeS s VVJeR-640. Processy teplomassoobmena i gidrodinamiki v sistemah bezopasnosti AJeS s VVJeR-640 [Methodical Specifics of Substantiation of PP Passive Safety Systems with VVER-640: Proceedings ]: sb. trudov. – SPb: AOOT NPO CKTI, 1997, pp. 12–22. (in Russ.)

Bezlepkin V.V. Semashko S.E. Alekseev S.B. Vardanidze T.G. Petrov Yu.Yu. [Improvement of Passive Heat Removal System through Steam Generators (SG PHRS) at NPP with VVER-1200 in Context of Fukushima Accident]. Available at: http://www.gidropress.podolsk.ru/files/proceedings/mntk2013/autorun/article167-ru.htm (accessed 01.10.2013).

Sviridenko I.I., Shevelyov D.V., Polyakov O.V., Timofeev V.A., Sviridenko N.N. Passive Residual Heat Removal System for WWER with the Thermosiphon Heatexchange Equipment, Int. J. Energy for a Clean Envi-ronment, 2015, vol. 16, iss. 1–4, pр. 209–223. DOI: 10.1615/InterJEnerCleanEnv.2015015683

Sviridenko I.I. Passivnaja sistema otvoda ostatochnyh teplovydelenij [Passive Residual Heat Removal System] Ukraine Patent 81419, no. а200500392; decl. 17.01.2005; publ. 10.01.2008, Bul. no. 1. 5 p.

Sviridenko I.I., Sukhov A.K., Shevielov D.V., Polyakov A.V. [Thermosiphon Based Heat Exchanger of WWER 1000 Primary Circuit Passive Residual Heat Removal System]. Zbіrnik naukovih prac' SNUJaEtaP [Coll. Sci. Works SNUNEI], 2013, no. 1(45), pp. 54–67. (in Russ.)

Published

2016-11-04

Issue

Section

Heat-power engineering