Using Leakage Currents to Evaluate the Induction Motor Insulation Condition

Authors

  • V. P. Metelkov Ural Federal University, Ekaterinburg
  • M. Yu. Borodin Ural Federal University, Ekaterinburg
  • K. A. Kondakov Ural Federal University, Ekaterinburg
  • K. E. Nesterov Ural Federal University, Ekaterinburg

DOI:

https://doi.org/10.14529/power190108

Keywords:

electric motor, winding, insulation, leakage currents, condition monitoring

Abstract

The need to improve the reliability and reduce the stator winding-related accident rates of asynchronous electric drives is what makes this topic relevant. The goal hereof is to find how capacitive leakage currents could be used to indicate the condition of the stator winding insulation in an asynchronous motor. The paper presents some results of studies into the stator winding insulation leakage currents generated by rectangular voltage pulses at 100 to 2000 Hz. The researchers have verified the ability to register leakage current parameters as a function of voltage pulse amplitude and frequency in order to use such data to find the insulation condition. 

It is shown that rectangular voltage pulses can produce sufficiently large leakage currents for easier use. Even rather simple and low-cost equipment is usable to that end. However, reliable determination of the leakage current peaks amplitude requires a very long measurement with numerous transmitted pulses; alternatively, one could use very high-resolution equipment with a sampling time of 10-6 s or less. Nevertheless, the equipment used in the tests does extract the data regarding the effective capacitive leakage currents, which could be used to diagnose the insulation.

Author Biographies

V. P. Metelkov, Ural Federal University, Ekaterinburg

-

M. Yu. Borodin, Ural Federal University, Ekaterinburg

-

K. A. Kondakov, Ural Federal University, Ekaterinburg

-

K. E. Nesterov, Ural Federal University, Ekaterinburg

-

References

Neti P., Younsi K., Shah M. A Novel High Sensitivity Differential Current Transformer for Online Health Monitoring of Industrial Motor Ground-Wall Insulation. Proc. Energy Conversion Congr. and Exposition, 15–19 Sept. 2013, Denver, USA, pp. 2493–2499. DOI: 10.1109/ecce.2013.6647022

Siddique A.S., Yadava G.S., Singh B. A Review of Stator Fault Monitoring Techniques of Induction Motors. IEEE Trans. Energy Conversion, 2005, vol. 20, pp. 106–114. DOI: 10.1109/tec.2004.837304

Sin M.L., Soong W.L., Ertugrul N. Induction Machine On-Line Condition Monitoring and Fault Diagnosis – A Survey. AUPEC 2003, Australasian Universities Power Engineering Conference, 28 Sept. – 1 Oct. 2003, Christchurch, New Zealand, pp. 1–6.

Zhang P., Du Y., Habetler T., Lu B. A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors. IEEE Transactions on Industry Applications, 2011, vol.47, pp. 34–46. DOI: 10.1109/tia.2010.2090839

Vedyashkin M.V., Muravlev O.P. [Estimation of Parameters of the Stator Windings Failures Distribution Laws during Operation of Crane Asynchronous Motors]. Izvestiya Tomskogo politekhnicheskogo universiteta [Bulletin of the Tomsk Polytechnic University], 2011, vol. 319, no. 4, pp. 117–121. (in Russ.)

Tonkikh V.G. Metod diagnostiki asinkhronnykh elektrodvigateley v sel'skom khozyaystve na osnove analiza parametrov ikh vneshnego magnitnogo polya. Dis. kand. tekhn. nauk [Method for Diagnosing Asynchronous Electric Motors in Agriculture Based on the Analysis of the Parameters of Their External Magnetic field. Cand. sci. diss.]. Barnaul, 2009. 181 p.

Kuznetsov N.L. Nadezhnost' elektricheskikh mashin [The Reliability of Electrical Machines]. Moscow, MEI Publ. House, 2006. 432 p.

Stone G.C., Boulter E. A., Culbert I., Dhirani H. Electrical Insulation for Rotating Machines: Design, Evaluation, Aging, Testing, and Repair. New Jersey, IEEE Computer Society Press, 2004. 252 p. DOI: 10.1002/9781118886663

Tanver P.J., Penman J. Condition Monitoring Electrical Machines. Hertfordshire, U.K., Research Studies Press, 1987. 282 p.

Babel A.S., Strangas E.G. Condition-Based Monitoring and Prognostic Health Management of Electric Machine Stator Winding Insulation. Conf. Proc. 21st International Conference on Electrical Machines, ICEM 2014, Sept. 2–5, 2014, Berlin, Germany, pp. 1855–1861. DOI: 10.1109/icelmach.2014.6960436

Younsi K., Neti P., Shah M., Zhou J., Krahn J., Weeber K., Whitefield C. On-Line Capacitance and Dissipation Factor Monitoring of AC Stator Insulation. IEEE Trans. Dielectr. Electr. Insul., 2010, vol. 17, no. 5, pp. 1441–1452. DOI: 10.1109/tdei.2010.5595545

Stashko V.I., Gubin I.B. [Simulation of the Insulation State of the Asynchronous Motors Windings of Seasonally Operated Equipment Based on the Use of Wave Transient Indicators]. Polzunovskiy vestnik [Polzunov Bulletin], 2002, no. 1, pp. 51–56. (in Russ.)

Nussbaumer P., Vogelsberger M., Wolbank T. Exploitation of Induction Machine’s High-Frequency Behavior for Online Insulation Monitoring. 9th IEEE Int. Symp. on Diagnostics for Electric Machines, Power Electron. and Drives, Aug 27, 2013, Valencia, Spain. pp. 579–585. DOI: 10.1109/demped.2013.6645773

Nussbaumer P., Wolbank T., Vogelsberger M. Separation of Disturbing Influences on Induction Machine’s High-Frequency Behavior to Ensure Accurate Insulation Condition Monitoring. 28th IEEE. Appl. Power Electron. Conference and Exposition, 17–21 March, 2013, Long Beach, USA, pp. 1158–1163. DOI: 10.1109/apec.2013.6520445

Vorob'ev N.P., Vorob'eva S.N., Sukhankin G.V., Gertsen N.T [Methods and Instruments for Diagnosing Insulation of Asynchronous Motors]. Polzunovskiy vestnik [Polzunov Bulletin], 2011, no. 2/2, pp. 261–269.

(in Russ.)

Gutov I.A. Prognozirovanie sostoyaniya elektrodvigateley na osnove ispol'zovaniya mnogo faktornykh modeley stareniya izolyatsii. Dis. kand. tekhn. nauk [Predicting the State of Electric Motors Based on the Use of Multivariate Models of Insulation Aging. Cand. sci. diss.]. Barnaul, 1997. 259 p.

Sidel'nikov L.G., Afanas'ev D.O. [Review of Methods for Monitoring the Technical Condition of Asynchronous Motors in Operation]. Vestnik PNIIPU. Geologiya. Neftegazovoe i gornoe delo [Bulletin PNIIPU. Geology. Oil, Gas and Mining], 2013, no. 7, pp. 127–137. (in Russ.)

Belousova N. V., Kalyavin V.P., Mozgalevskiy A.V. Opyt testovogo diagnostirovaniya obmotok elektricheskikh mashin [Experience of Test Diagnosis of Electric Machine Windings]. Leningrad, LDNTP, 1989. 24 p.

Levachev A.V. Diagnostika izolyatsii asinkhronnykh elektrodvigateley na osnove ispol'zovaniya parametrov skhemy zameshcheniya obmotok. Dis. kand. tekhn. nauk [Asynchronous Electric Motors Insulation Diagnostics Based on the Use of Parameters of a Winding Replacement Circuit. Cand. sci. diss.]. Barnaul, 2002. 167 p.

Published

2019-04-12

Issue